Engineering Records Retention
The Engineering Records Retention carries 4 published figures read from 4 sources' own pages, from 3 to 15 year, read 7 November 2026.
Read in full on 7 November 2026: 4 of 8 named sources state a figure; 4 state none.
By record type
| Breakdown | Median | Range | Sources |
|---|---|---|---|
| record type deed (specialty) limitation period | 12 year (one figure) | one figure, no range | 1 |
| record type simple contract limitation period | 6 year (one figure) | one figure, no range | 1 |
| record type negligence longstop limitation period | 15 year (one figure) | one figure, no range | 1 |
| record type federal A/E contract records (FAR 4.703, 3 years after final payment) | 3 year (one figure) | one figure, no range | 1 |
The published figures, each beside its source
Each row is one published figure: what the source's own page states, a link to that page and the date we read it. Nothing appears here that a source did not publish.
| Source | Figure | Breakdown | Read |
|---|---|---|---|
| Limitation Act 1980 s.14B - fifteen-year longstop for negligence | 15 year | negligence longstop limitation period | 2026-11-02 |
| Limitation Act 1980 s.8 - twelve years on a deed | 12 year | deed (specialty) limitation period | 2026-09-12 |
| Limitation Act 1980 s.5 - six years on a simple contract (design appointments) | 6 year | simple contract limitation period | 2026-09-12 |
| FAR 4.703 - contractor records retention (federal A/E contracts) | 3 year | federal A/E contract records (FAR 4.703, 3 years after final payment) | 2026-11-07 |
The source sentences behind the table (4)
- Limitation Act 1980 s.14B - fifteen-year longstop for negligence, read 2026-11-02:
An action for damages for negligence, other than one to which section 11 [F2or 11ZA] of this Act applies, shall not be brought after the expiration of fifteen years from the date (or, if more than one, from the last of the dates) on which there occurred any act or omission—
- Limitation Act 1980 s.8 - twelve years on a deed, read 2026-09-12:
An action upon a specialty shall not be brought after the expiration of twelve years from the date on which the cause of action accrued.
- Limitation Act 1980 s.5 - six years on a simple contract (design appointments), read 2026-09-12:
An action founded on simple contract shall not be brought after the expiration of six years from the date on which the cause of action accrued.
- FAR 4.703 - contractor records retention (federal A/E contracts), read 2026-11-07:
(1) 3 years after final payment; or
No published figure on these pages
These 4 named sources were read on the dates shown and state no figure. They are part of the count and stay blank.
- Building Safety Act 2022 s.88 - keeping information about higher-risk buildings (golden thread), read 2026-11-07: read in full and no accepted figure on the page
- Building Regulations 2010 reg.38 - fire safety information, read 2026-11-07: every candidate on the page was refused
- ARB, Architects Code: Standards of Conduct and Practice, read 2026-09-21: every candidate on the page was refused
- FAR 52.215-2 - audit and records clause, read 2026-11-07: every candidate on the page was refused
How we read and count
Method: a source counts only through a sentence printed on its own page, saved exactly as written with the read date and a checksum of the page text.
8 sources could be read; 4 publish a figure we could use and 4 publish none, recorded as such with nothing filled in.
1 could not be read and are excluded.
Each source contributes one figure, in year, to the median, range and quartiles.
Review set aside 26 candidate sentence(s) and noted why.
Still to come for this dataset (for now the figures are each source's own): one row per record type per jurisdiction: CDM health and safety file, Building Safety Act golden-thread information, fire safety information, federal A/E contract records, and the limitation periods (6 years contract, 12 years deed, 15-year negligence longstop; FAR 3 years after final payment) that set how long a practice in practice keeps its files; the longest period that binds any one project.
26 candidate sentences on these pages failed review, and each failure is recorded with its reason.
Where we looked (9)
- CDM Regulations 2015 reg.12 - construction phase plan and health and safety file(quoted for comment under the publisher's terms)
- Building Safety Act 2022 s.88 - keeping information about higher-risk buildings (golden thread)(quoted for comment under the publisher's terms)
- Building Regulations 2010 reg.38 - fire safety information(quoted for comment under the publisher's terms)
- Limitation Act 1980 s.5 - six years on a simple contract (design appointments)(quoted for comment under the publisher's terms)
- Limitation Act 1980 s.8 - twelve years on a deed(quoted for comment under the publisher's terms)
- Limitation Act 1980 s.14B - fifteen-year longstop for negligence(quoted for comment under the publisher's terms)
- ARB, Architects Code: Standards of Conduct and Practice(quoted for comment under the publisher's terms)
- FAR 4.703 - contractor records retention (federal A/E contracts)(quoted for comment under the publisher's terms)
- FAR 52.215-2 - audit and records clause(quoted for comment under the publisher's terms)
Take this figure with you
The Engineering Records Retention carries 4 published figures read from 4 sources' own pages, from 3 to 15 year, read 7 November 2026.
Read in full on 7 November 2026: 4 of 8 named sources state a figure; 4 state none.
Engineering Records Retention, record type deed (specialty) limitation period: median 12 year across 1 source, read 7 November 2026.
Engineering Records Retention, record type simple contract limitation period: median 6 year across 1 source, read 7 November 2026.
Engineering Records Retention, record type negligence longstop limitation period: median 15 year across 1 source, read 7 November 2026.
Engineering Records Retention, record type federal A/E contract records (FAR 4.703, 3 years after final payment): median 3 year across 1 source, read 7 November 2026.
To cite: "sellengineeringdatatoai.com Engineering Records Retention", updated 2026-11-07, https://sellengineeringdatatoai.com/datasets/engineering-records-retention/.
The data as a CSV (4 rows, updated 2026-11-07)
Questions this data answers
Which project records must a design practice keep, and for how long?
The Engineering Records Retention carries 4 published figures read from 4 sources' own pages, from 3 to 15 year, read 7 November 2026.
Where do the figures in the Engineering Records Retention come from?
Every figure is quoted from its source's own page and dated (last read 7 Nov 2026). 8 named sources were read and 4 publish a figure; the 4 that publish none are recorded as not published, never estimated.